Performance of the beam position monitor system of the final focus test beam

Citation
S. Smith et al., Performance of the beam position monitor system of the final focus test beam, NUCL INST A, 431(1-2), 1999, pp. 9-26
Citations number
10
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
431
Issue
1-2
Year of publication
1999
Pages
9 - 26
Database
ISI
SICI code
0168-9002(19990711)431:1-2<9:POTBPM>2.0.ZU;2-Q
Abstract
The Beam Position Monitor (BPM) system for the Final Focus Test Beam (FFTB) at SLAG is designed to meet challenging specifications in the areas of sin gle-pulse resolution, ab initio installation accuracy, and time-stability o f BPM electrical centroids. We review the tolerances on these quantities an d the technical choices made to achieve same, and detail the results of sev eral studies of the actual performance of the system. These results are the n related to the BPM system requirements for a future high-energy e(+)e(-) linear collider. (C) 1999 Elsevier Science B.V. All rights reserved.