Direct load control using fuzzy dynamic programming

Citation
Ht. Yang et Ky. Huang, Direct load control using fuzzy dynamic programming, IEE P-GEN T, 146(3), 1999, pp. 294-300
Citations number
15
Categorie Soggetti
Eletrical & Eletronics Engineeing
Journal title
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION
ISSN journal
13502360 → ACNP
Volume
146
Issue
3
Year of publication
1999
Pages
294 - 300
Database
ISI
SICI code
1350-2360(199905)146:3<294:DLCUFD>2.0.ZU;2-M
Abstract
The paper develops a fuzzy dynamic programming (FDP) approach to solving th e direct load control (DLC) problem of large air conditioner loads (ACLs). In the formulation, the cycling capacities of the ACLs and the system load demands are all regarded as fuzzy variables. The scheduling of the DLC and the unit commitment (UC) is integrated into an FDP structure to reduce the system peak loads as well as the system operation costs. The solution appro ach has been tested on the data for the Taiwan Power (Taipower) 38-unit sys tem with 15 ACL groups. In the tests, the Monte-Carlo simulation technique is employed to assess the robustness of the solution obtained from. the pro posed FDP approach for various load uncertainties. The results are presente d and compared to those without consideration of the load uncertainties.