Homogeneity studies of multifilamentary BSCCO tapes by three-axis Hall sensor magnetometry

Citation
J. Paasi et al., Homogeneity studies of multifilamentary BSCCO tapes by three-axis Hall sensor magnetometry, IEEE APPL S, 9(2), 1999, pp. 1598-1601
Citations number
10
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
ISSN journal
10518223 → ACNP
Volume
9
Issue
2
Year of publication
1999
Part
2
Pages
1598 - 1601
Database
ISI
SICI code
1051-8223(199906)9:2<1598:HSOMBT>2.0.ZU;2-E
Abstract
A new generation of Hall sensor magnetometer for non-destructive studies of superconductor homogeneity is proposed and tested. The magnetometer allows us to measure the three-dimensional spatial dependence of all three compon ents of magnetic field produced by applied or induced currents in the condu ctor. This new technique is more sensitive to detect small obstacles in the current path than the old Hall sensor techniques measuring only the field component perpendicular to the flat surface of the conductor. Having presen ted the measurement system,the method is demonstrated by experiments on mul tifilamentary BSCCO tapes.