AC losses in multi-filamentary tapes depend on various parameters. Among th
em, geometrical factors such as overall tape width and thickness as well as
the precise arrangement of the filaments are expected to have an important
influence. Several theoretical models describe this dependency. In order t
o study these geometrical effects experimentally, we prepared a series of B
i(2223)/Ag tapes with gradually changing filament arrangements and tape asp
ect ratio, and characterized them by AC transport and magnetic measurements
. The results are compared to model predictions.