An analysis of the discharge of the Barrel Toroid under several operating c
onditions has been carried out. The main critical parameters of the dischar
ge (i.e. the maximum temperature inside the coils, the maximum temperature
gradient, the maximum voltage at the coil ends and the maximum decentering
forces acting on the BT and ECT magnets) have been calculated for several o
perating conditions theaters on, heaters off, short circuit with heaters on
or off).
The aim of this analysis is to provide a cross check of the protection desi
gn of the Barrel Toroid coils [1] with an independent study. The results va
lidate the choice to use a low value of dump resistance, and give some impo
rtant warning in the case of heater failure or presence of a short circuit.