Measuring AC-loss in high temperature superconducting cable-conductors using four probe methods

Citation
A. Kuhle et al., Measuring AC-loss in high temperature superconducting cable-conductors using four probe methods, IEEE APPL S, 9(2), 1999, pp. 1169-1172
Citations number
15
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
ISSN journal
10518223 → ACNP
Volume
9
Issue
2
Year of publication
1999
Part
1
Pages
1169 - 1172
Database
ISI
SICI code
1051-8223(199906)9:2<1169:MAIHTS>2.0.ZU;2-7
Abstract
Measuring the AC-loss of superconducting cable conductors have many aspects in common with measuring the AC-loss of single superconducting tapes. In a cable conductor all tapes are connected to each other and to the test circ uit through normal metal joints in each end. This makes such measurements c onsiderably more complex, especially for samples of laboratory scale (1-5 m eters). Here we discuss different measurement configurations using four pro be methods and lock-in detection. We conclude that the voltage should be pi cked up at end of the connecting joints, and we show how the resistive cont ribution from these joints can be identified and subtracted from the measur ed data. We also show measurements which indicate that the size of the loop constituted by the voltage leads has no influence on the measurements.