Application of ultrasound in callus distraction of the hypoplastic mandible: an additional method for the follow-up

Citation
Th. Juenger et al., Application of ultrasound in callus distraction of the hypoplastic mandible: an additional method for the follow-up, J CRAN MAX, 27(3), 1999, pp. 160-167
Citations number
23
Categorie Soggetti
Dentistry/Oral Surgery & Medicine
Journal title
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY
ISSN journal
10105182 → ACNP
Volume
27
Issue
3
Year of publication
1999
Pages
160 - 167
Database
ISI
SICI code
1010-5182(199906)27:3<160:AOUICD>2.0.ZU;2-7
Abstract
Mandibular callus distraction was performed on 14 patients. In addition to established radiological methods, sonography was performed to monitor the c linical progress. Ultrasound shows a precise picture of all interesting ite ms in distraction treatment. Although the value of radiographs is not obsol ete completely, sonography was found to be a meaningful supplement in the c linical monitoring of callus distraction. Furthermore the method is capable of early recognition of complications and it can reduce X-ray exposure.