Activation of water in the cooling system at the pulsed spallation neutronsource, KENS
Citation
S. Itoh et al., Activation of water in the cooling system at the pulsed spallation neutronsource, KENS, J PHYS CH S, 60(8-9), 1999, pp. 1557-1559
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS
SICI code
0022-3697(199908/09)60:8-9<1557:AOWITC>2.0.ZU;2-Z
Abstract
We measured the radioactivity of Be-7 and H-3 in the ambient-temperature wa
ter moderator cooling system at the pulsed spallation neutron source, KENS,
The detected activity of H-3 in cooling water was in agreement with the pr
oduction estimated from the neutron flux obtained from a neutronic calculat
ion, however, the results of 7Be was only about 0.1% of the estimation. We
tried to investigate the distribution of Be-7 trapped in the cooling system
. We also measured the time constants of the trapping process, and the resu
lt suggests that a large amount of the produced 7Be is trapped in parts of
the cooling system with a very short time constant. (C) 1999 Elsevier Scien
ce Ltd. All rights reserved.