In order to study alternative dose determination methods, the bulk etching
velocity and the latent track annealing of LR 115 track detectors was studi
ed during electron irradiation runs from a Pelletron accelerator. For this
purpose alpha irradiated and blank detectors were exposed to increasing ele
ctron doses from 10.5 to 317.5 kGy. After the irradiation with electrons th
e detectors were etched under routine conditions, except for the etching ti
me, that was varied for each electron dose in order to reach a fixed residu
al thickness. The variation of the bulk etching velocity as a function of e
ach one of the electron doses supplied, was interpolated in order to obtain
dosimetric response curves. The observed annealing effect on the latent tr
acks is discussed as a function of the total electron doses supplied and th
e temperature.