Qualification tests of coatings for inner walls in a BWR reactor

Citation
M. Balcazar et al., Qualification tests of coatings for inner walls in a BWR reactor, RADIAT MEAS, 31(1-6), 1999, pp. 697-700
Citations number
2
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
RADIATION MEASUREMENTS
ISSN journal
13504487 → ACNP
Volume
31
Issue
1-6
Year of publication
1999
Pages
697 - 700
Database
ISI
SICI code
1350-4487(199906)31:1-6<697:QTOCFI>2.0.ZU;2-W
Abstract
Qualification tests of coatings for inner walls in a Boiling Water Reactor (BWR) were performed under request for decontamination purposes. Several ty pes of coatings were contaminated with fission products obtained from a UO2 ,solution irradiated in a nuclear research reactor,afterwards a successive decontamination process according with standards based on gamma activity wa s applied. In each decontamination stage, alpha and gamma activity measurem ents were made on the probes. Results obtained for cl activity using nuclea r track detectors are presented as an alternative assessment method during the decontamination process.