The aim of this study is to characterise benign from malignant breast
lesions by using 99mTc-Tetrofosmin, Materials: Fifteen female patients
with suspected breast lesions and ten normal controls underwent breas
t scintigraphy with 99mTc-Tetrofosmin. All patients had conventional m
ammography. Breast imaging begun 20 minutes after i.v. injection of 74
0 MBq 99mTc-Tetrofosmin. Patients were imaged in supine and prone posi
tion. Results of the 15 patients with suspected breast lesions, 13 sho
wed breast uptake, and 6 of them had suspicious lesions on mammography
. Surgery confirmed 10 carcinomas and 3 benign lesions. Two patients d
emonstrated no abnormal accumulation or suspicious findings in mammogr
aphy. None of the normal controls had breast uptake or mammographic ab
normalities. Our study has a sensibility of 100% and 60%, and a specif
icity of 80% and 100% in scintigraphy and mammography respectively. Co
nclusion: Our findings suggest that 99mTc-Tetrofosmin may play a role
in evaluating breast masses and that can differentiate benign from mal
ignant lesions.