Hi. Manninen et al., Comparison of iodixanol 270 with iohexol 300 in infrapopliteal arteriography - Digital densitometric analysis of angiographic opacification, ACT RADIOL, 40(3), 1999, pp. 291-295
Purpose: To compare iodixanol 270 mg I/ml with iohexol 300 mg I/ml in infra
popliteal arteriography by measuring digital densitometric vessel opacifica
tion and by visually assessing angiographic enhancement.
Material and Methods: In a double-blind, dual-balanced, dr-sequence crossov
er design, 50 claudicant patients received two contrast media injections (1
0 min interval) in the superficial femoral artery. Digital angiography was
performed at 8 frames/s and time-density curves with a circular region of i
nterest over a distal calf artery were generated. A mixed, linear model was
used to identify effects influencing the density measurements. Subjective
evaluation of the image quality was made independently by two observers.
Results: No statistically significant difference between the contrast media
was revealed in the analysis of the densitometric measurements (p=0.14) no
r in the subjective visual evaluation (p=0.74). However, the mean density a
t the time of maximum opacification was higher after the first injection th
an that after the second injection (p=0.02). There was a tendency towards l
ower intensity of warmth during injection of iodixanol 270 than during inje
ction of iohexol 300.
Conclusion: In patients with severe occlusive atherosclerotic disease, iodi
xanol yielded the same image quality as iohexol in infrapopliteal arteriogr
aphy, in spite of the 30 mg I/ml lower iodine concentration.