Comparison of commercial Amies transport systems with in-house Amies medium for recovery of Neisseria gonorrhoeae

Citation
Ds. Thompson et Sa. French, Comparison of commercial Amies transport systems with in-house Amies medium for recovery of Neisseria gonorrhoeae, J CLIN MICR, 37(9), 1999, pp. 3020-3021
Citations number
5
Categorie Soggetti
Clinical Immunolgy & Infectious Disease",Microbiology
Journal title
JOURNAL OF CLINICAL MICROBIOLOGY
ISSN journal
00951137 → ACNP
Volume
37
Issue
9
Year of publication
1999
Pages
3020 - 3021
Database
ISI
SICI code
0095-1137(199909)37:9<3020:COCATS>2.0.ZU;2-B
Abstract
Microbiologists are still encumbered by the variable performance of Amies c harcoal transport medium in recovery of Neisseria gonorrhoeae. The objectiv e of this study was to evaluate and select a good quality commercial system to replace our in-house preparation. We adsorbed 0.1 mi of a suspension fr om 30 gonococcal isolates onto each swab type and replaced the swab into th e transport medium. We plated the swabs to New York City medium at 0, 24, 4 8, 72, and 96 h. We compared the survival of each isolate in the commercial Amies transport systems with that in our in-house Amies transport medium. The best recovery was observed with Copan transport systems. Some systems a re inadequate and unacceptable far culture of gonococci.