Sp. Simakov et al., Benchmarking of evaluated neutron data for nickel by 14-MeV spherical shell transmission experiments, FUSION TECH, 36(2), 1999, pp. 173-180
The results of a transmission experiment on a spherical nickel shell with a
7.5-cm-thick wall and a 14-MeV neutron point source at the center are repo
rted. The neutron leakage spectrum from 14 MeV down to 100 keV was measured
by the time-of-flight (TOF) method. Descriptions of the experimental arran
gement, TOF spectrometer, measurements, and data-reduction procedures are g
iven. The measured data are compared with results obtained in other laborat
ories. Three-dimensional Monte Carlo calculations with the MCNP code using
the FENDL-1, EFF-2.4, and JENDL-FF nuclear data libraries were made. The FE
NDL-1 library predicted the neutron leakage from nickel more accurately tha
n the other libraries.