P. Britz-mckibbin et al., Analysis of epinephrine from fifteen different dental anesthetic formulations by capillary electrophoresis, J CHROMAT A, 853(1-2), 1999, pp. 535-540
A robust method for the quantification of epinephrine from 15 different com
mercial dental anesthetic formulations is developed using CE. This work pre
sents an extension to a method reported earlier. The solvability of several
anesthetic compounds was improved through appropriate dilutions and the ad
dition of sodium dodecyl sulfate to the separation background electrolyte.
By controlling the mobility of the analyte at different pH values, a dilute
solution of epinephrine is focused into a sharp zone with the injection of
about 150 nl of anesthetic solution into the capillary. This on-column con
centration technique extended the concentration detection limit of epinephr
ine to about 5.0 x 10(-7) M using a commercially available UV detector. A c
orrelation plot between the measured and listed epinephrine concentration f
or the 15 dental anesthetic solutions demonstrated excellent accuracy of th
is method. (C) 1999 Elsevier Science B.V. All rights reserved.