Using an h-monitor, surface heat flux and effective surface heat transfer c
oefficients were evaluated during baking of two cakes in a tunnel-type mult
i-zone industrial oven. An average 75-80% of total heat flux was counted as
radiation heat. Air-mass temperature outside the boundary layer was determ
ined from the experimental temperature profiles over the h-monitor top plat
e. In the range of baking temperatures (186-225 degrees C), relative air ve
locities (0.02-0.437 m/s) and absolute humidities (0.0267-0.0428 kg H2O/kg
dry air) heat transfer coefficients were 20 to 48.0 W/m(2)K, A simple regre
ssion model was developed based on experimental data.