Alignment of the HERA-B RICH optical system with data

Citation
A. Gorisek et al., Alignment of the HERA-B RICH optical system with data, NUCL INST A, 433(1-2), 1999, pp. 408-412
Citations number
3
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN journal
01689002 → ACNP
Volume
433
Issue
1-2
Year of publication
1999
Pages
408 - 412
Database
ISI
SICI code
0168-9002(19990821)433:1-2<408:AOTHRO>2.0.ZU;2-6
Abstract
We present a method for alignment of the mirror segments in the Ring Image Cherenkov Counter of the HERA-B spectrometer. The method will use recorded data, and was tested by using simulated events. The study shows that the: m irrors can be aligned accurately enough to make the corresponding error in Cherenkov angle measurement negligible compared to other contributions. The mirrors are aligned relative to one mirror segment which can be chosen arb itrarily. (C) 1999 Elsevier Science B.V. All rights reserved.