A simple method was developed for measuring the paracetamol concentrat
ion in human serum by reversed-phase HPLC. The suggested method is suf
ficiently precise, sensitive, and selective. The time of proper analys
is does not exceed 15 min. The linear response of the detector has bee
n proved for the range of 1-80 mg.l(-1) paracetamol.