Air sampling studies are described which show high levels of airborne
starch powder contamination in areas where powdered latex gloves are u
sed. Furthermore, culture of collected samples show a clear associatio
n between starch particles and bacterial colonies in an experimental s
ystem suggesting that airborne particles could act as a vector for pat
hogens in the hospital environment.