Positron annihilation lifetime measurements were made on well calibrated fa
tigue samples of SS-304. Measurements were made on a high and low carbon al
loy. Two separate lifetimes, indicating two defect site types were resolved
in each sample. Significant Lifetime changes are observed to occur early i
n the fatigue cycles. (C) 1999 Elsevier Science B.V. All rights reserved.