Effective reluctivity calculation versus time step calculation of magneticshielding with ferromagnetic material

Citation
D. Lederer et al., Effective reluctivity calculation versus time step calculation of magneticshielding with ferromagnetic material, COMPEL, 18(3), 1999, pp. 410-421
Citations number
9
Categorie Soggetti
Eletrical & Eletronics Engineeing
Journal title
COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING
ISSN journal
03321649 → ACNP
Volume
18
Issue
3
Year of publication
1999
Pages
410 - 421
Database
ISI
SICI code
0332-1649(1999)18:3<410:ERCVTS>2.0.ZU;2-Q
Abstract
The calculation of magnetic shielding with ferromagnetic material by an eff ective reluctivity method and a time step method based on the finite elemen t calculation is investigated The calculation results of both methods are c ompared with measurement results and with each other in order to check thei r reliability and accuracy. It turns out that both methods give similar res ults for the field inside the shielding material, whereas in the surroundin g air the effective reluctivity method gives more accurate results than the present time step method.