Jr. Fan et al., Numerical and experimental investigation on the reduction of NOx emission in a 600 MW utility furnace by using OFA, FUEL, 78(12), 1999, pp. 1387-1394
The paper describes a three-dimensional computer simulation, developed to p
redict the formation of nitric oxide in a tangentially fired boiler furnace
burning pulverized fuel. The model was applied to a 600 MW utility boiler
under different operating conditions. As fuel nitrogen is released in propo
rtion to burnout of pulverized coal particles, the particles are treated in
a Lagrangian framework in order to track burning pulverized coal particles
through the gas continuum. The prediction yields encouraging results compa
red to experimental data. (C) 1999 Elsevier Science Ltd. All rights reserve
d.