For the semiactive vibration control, a variable damper and proper control
systems are essential. In this research a controllable damper was designed
using the MR fluids and its mechanical properties such as damping constant
and response time were measured.
Since the response time of the MR damper was much longer than nominal MR fl
uid response time, the time delay of the damper should be considered in the
design of controllers. It is shown that the advanced on/off vibration cont
rol which includes the damper time delay performs more effectively than the
conventional one.