We used a collisional cooling cell which was designed to mount directly on
the second stage of a CTI-cryogenics Model 22C CRYODYNE CRYOCOOLER. The cel
l was maintained at approximately 14 K for all measurements reported here.
The absorption path length in the cell was 4.2 cm and the window clear aper
ture was 1.27 cm. The position of the injector was designed to be adjustabl
e, so we could probe the cold gas cloud from the exit plane of the injector
along a vertical line to approximately 11 mm downstream from the injector.
We also probed the cloud in a horizontal direction, orthogonal to the prev
ious direction. Our beam is imaged to a spot diameter of approximately 1 mm
in the center of the cell. Gas temperatures as low as 24 K were measured a
pproximately 11 mm from the nozzle and temperatures of approximately 40 K w
ere measured close to the exit plane of the nozzle. Carbon monoxide was use
d for all measurements. (C) 1999 Elsevier Science B.V. All rights reserved.