Thermoelectric measurements for bondability analysis of bond pads: a new concept for a bondability analyser

Citation
P. Groning et al., Thermoelectric measurements for bondability analysis of bond pads: a new concept for a bondability analyser, SURF INT AN, 28(1), 1999, pp. 191-194
Citations number
4
Categorie Soggetti
Physical Chemistry/Chemical Physics
Journal title
SURFACE AND INTERFACE ANALYSIS
ISSN journal
01422421 → ACNP
Volume
28
Issue
1
Year of publication
1999
Pages
191 - 194
Database
ISI
SICI code
0142-2421(199908)28:1<191:TMFBAO>2.0.ZU;2-B
Abstract
We present a new apparatus to determine the ultrasonic wire bonding behavio ur of different contact materials. The basic principle of the developed bon dability analyser is measurement of the temperature at the bond ball during the ultrasonic friction process by using a thermocouple instead of a bond wire. We tested the bondability analyser by analysing different bond pads w ith high and low bond contact quality and comparing the results with pull f orce measurements of the wire bond, The results show that the bondability a nalyser characterizes the ultrasonic wire bonding behaviour of bond pads pe rfectly, In addition, the apparatus allows the wire bonding process to be s tudied in detail and in real time. Copyright (C) 1999 John Wiley & Sons, Lt d.