T. Katayama et al., Solid-fluid biomimetic composites by considering load dispersion mechanismof cancellous bone structure (Consideration of honeycomb structure), JSME A, 42(3), 1999, pp. 355-361
Citations number
15
Categorie Soggetti
Mechanical Engineering
Journal title
JSME INTERNATIONAL JOURNAL SERIES A-SOLID MECHANICS AND MATERIAL ENGINEERING
The purpose of this research is to apply biomimetic designed composites to
artificial structures. Looking at the bio-joint mechanism, the solid-fluid
composite structure of the cancellous bone is likely to play a great import
ant role in the load transmission. So, the solid-fluid composite model equa
l to the cancellous bone was made by using honeycomb structure. Static inde
ntation testing was carried out, and in-plane deformation conditions of the
solid-fluid composite specimens were measured quantitatively. Experimental
results illustrated that the hydrostatic pressure of the fluid phase great
ly influenced on the in-plane deformation condition of the solid phase. Con
sequently, as for the solid-fluid composite models, the compressive load di
spersion by the solid-fluid phase interaction was expected.