This note introduces a design for a low-cost continuous digital output
water level recorder. The Stowaway(TM) volt data logger from Onset Co
mputer Corporation is modified to incorporate a steady voltage input.
A simple float-pulley system can be constructed, or the logger can be
attached to existing analog recorders. Laboratory and field accuracy t
ests indicate that the recorder is capable of producing reliable estim
ates of stage. In-field accuracy is a function of the float-pulley sys
tem and the choice of accuracy in the electronic components employed i
n the modification of the data logger.