Abstract
Magnetically induced superresolution by center aperture detection (MSR-CAD) using pulsed and conventional de schemes were applied to magneto-optical d isks to quantitatively evaluate readout performances. By simulation and exp eriments, it was found that carrier-to-noise ratio (CNR) in the pulsed-lase r readout was about 2.5 dB higher than that in the de readout scheme at mar k size of 0.45 mu m or shorter, Therefore, pulsed readout is feasible to im prove CNR and recording density in MSR-CAD disks.