Magnetic hysteresis loops have been measured for a 100 nm period array of 3
5 nm diameter nickel pyramids formed by interferometric lithography. Result
s are compared with a computational model which describes a square array of
Stoner-Wohlfarth particles. This allows the distribution of particle aniso
tropies and easy axis directions, and the switching mechanism, to be inferr
ed.