Evaluation of the cuff-leak test in a cardiac surgery population

Authors
Citation
M. Engoren, Evaluation of the cuff-leak test in a cardiac surgery population, CHEST, 116(4), 1999, pp. 1029-1031
Citations number
10
Categorie Soggetti
Cardiovascular & Respiratory Systems","Cardiovascular & Hematology Research
Journal title
CHEST
ISSN journal
00123692 → ACNP
Volume
116
Issue
4
Year of publication
1999
Pages
1029 - 1031
Database
ISI
SICI code
0012-3692(199910)116:4<1029:EOTCTI>2.0.ZU;2-T
Abstract
Objective: The purpose of this study is to determine the accuracy of the cu ff-leak test in a cardiovascular ICU, Methods: Five hundred twenty-four patients were tested immediately before b eing extubated 531 times. The cuff-leak test was performed with the ventila tor set in assist-control mode at a tidal volume (VT) of 10 to 12 mL/kg. Th e leak was taken to be the difference between the preset inspiratory VT and the average of the three lowest of the subsequent six expiratory VTs. A le ak less than or equal to 110 mt was considered to be a positive leak test, Results: None of the 20 patients with a positive leak test developed proble ms, Three patients had postextubation strider. Their leaks were 433, 312, a nd 350 mL. Conclusion: The cuff-leak test is inaccurate and cannot be recommended for routine use in this population.