Objective: The purpose of this study is to determine the accuracy of the cu
ff-leak test in a cardiovascular ICU,
Methods: Five hundred twenty-four patients were tested immediately before b
eing extubated 531 times. The cuff-leak test was performed with the ventila
tor set in assist-control mode at a tidal volume (VT) of 10 to 12 mL/kg. Th
e leak was taken to be the difference between the preset inspiratory VT and
the average of the three lowest of the subsequent six expiratory VTs. A le
ak less than or equal to 110 mt was considered to be a positive leak test,
Results: None of the 20 patients with a positive leak test developed proble
ms, Three patients had postextubation strider. Their leaks were 433, 312, a
nd 350 mL.
Conclusion: The cuff-leak test is inaccurate and cannot be recommended for
routine use in this population.