Fabricating auricular prostheses using three-dimensional soft tissue models

Citation
K. Penkner et al., Fabricating auricular prostheses using three-dimensional soft tissue models, J PROS DENT, 82(4), 1999, pp. 482-484
Citations number
10
Categorie Soggetti
Dentistry/Oral Surgery & Medicine
Journal title
JOURNAL OF PROSTHETIC DENTISTRY
ISSN journal
00223913 → ACNP
Volume
82
Issue
4
Year of publication
1999
Pages
482 - 484
Database
ISI
SICI code
0022-3913(199910)82:4<482:FAPUTS>2.0.ZU;2-5
Abstract
This article describes a method for fabricating an auricular prosthesis. Th is procedure uses the contours of the soft tissue surface from computerized tomography scans to fabricate a computer-generated, side-inverted 3-dimens ional soft tissue model from a solid block of polyurethane using an Endopla n milling machine. The resultant 3-dimensional soft tissue model can then b e used as the basis for a wax sculpture. This procedure facilitates the pla nning of the prosthesis; symmetrical modeling, especially for large, hemifa cial defects; and the impression, which can be made on the model itself.