Yw. Park et Yk. Chung, Leak-before-break assessment of CANDU pressure tube considering leak detection capability, NUCL ENG DE, 191(2), 1999, pp. 205-216
The leak before break (LBB) concept is employed as defense in depth in CAND
U reactors in order to avoid an unstable failure in pressure tubes. The LBB
in pressure tubes can be ensured when detection, confirmation and location
of the leak are carried out and the reactor is placed in a depressurized c
ondition before the crack exceeds critical crack length. Leak detection and
location is provided by the annulus gas system (AGS). Therefore, the evalu
ation parameters for LBB assessment, such as leak detection and leak locati
on capabilities, should be made available through AGS performance test. Rec
ently, the AGS in-situ tests with a simulated moisture injection were carri
ed out in one of the CANDU reactors in Korea. This paper presents the LBB a
ssessment performed taking into account the leak detection capability and t
he modification of operating procedure therefrom. (C) 1999 Elsevier Science
S.A. All rights reserved.