Leak-before-break assessment of CANDU pressure tube considering leak detection capability

Citation
Yw. Park et Yk. Chung, Leak-before-break assessment of CANDU pressure tube considering leak detection capability, NUCL ENG DE, 191(2), 1999, pp. 205-216
Citations number
8
Categorie Soggetti
Nuclear Emgineering
Journal title
NUCLEAR ENGINEERING AND DESIGN
ISSN journal
00295493 → ACNP
Volume
191
Issue
2
Year of publication
1999
Pages
205 - 216
Database
ISI
SICI code
0029-5493(199907)191:2<205:LAOCPT>2.0.ZU;2-Y
Abstract
The leak before break (LBB) concept is employed as defense in depth in CAND U reactors in order to avoid an unstable failure in pressure tubes. The LBB in pressure tubes can be ensured when detection, confirmation and location of the leak are carried out and the reactor is placed in a depressurized c ondition before the crack exceeds critical crack length. Leak detection and location is provided by the annulus gas system (AGS). Therefore, the evalu ation parameters for LBB assessment, such as leak detection and leak locati on capabilities, should be made available through AGS performance test. Rec ently, the AGS in-situ tests with a simulated moisture injection were carri ed out in one of the CANDU reactors in Korea. This paper presents the LBB a ssessment performed taking into account the leak detection capability and t he modification of operating procedure therefrom. (C) 1999 Elsevier Science S.A. All rights reserved.