3D-radiographic analysis does not improve the Neer and AO classifications of proximal humeral fractures

Citation
Goj. Sjoden et al., 3D-radiographic analysis does not improve the Neer and AO classifications of proximal humeral fractures, ACT ORTH SC, 70(4), 1999, pp. 325-328
Citations number
17
Categorie Soggetti
Ortopedics, Rehabilitation & Sport Medicine","da verificare
Journal title
ACTA ORTHOPAEDICA SCANDINAVICA
ISSN journal
00016470 → ACNP
Volume
70
Issue
4
Year of publication
1999
Pages
325 - 328
Database
ISI
SICI code
0001-6470(199908)70:4<325:3ADNIT>2.0.ZU;2-5
Abstract
The Neer and AO fracture classifications for fractures of the proximal hume rus have shown poor reproducibility based on plain radiography, We wanted t o investigate whether the addition of 3-dimensional (3D) reconstructions wo uld increase the reproducibility of classification. 7 observers independent ly classified 24 fractures of the proximal humerus using both plain radiogr aphs, CT and 3D and the classification was repeated 2 months later. There was a moderate interobserver agreement when using the Neer classifica tion, but only a fair agreement with the AO classification. The Neer system had a mean kappa value of 0.44 and the AO had a value of 0.32 for the firs t assessment. In the second assessment, the mean kappa values were 0.49 and 0.34, respectively. Intraobserver reproducibility was fair to substantial agreement for Neer (kappa range 0.27-0.73) and for AO (kappa range 0.29-0.7 4). In conclusion, the addition of CT and 3D to plain radiographs did not impro ve the reproducibility of the classifications of Neer and AO of the proxima l humerus.