Kinetics of the active medium of a multiwave IR xenon laser in hard-ioniser-pumped mixtures with He and Ar. II. Nuclear pumping

Citation
Av. Karelin et Ov. Simakova, Kinetics of the active medium of a multiwave IR xenon laser in hard-ioniser-pumped mixtures with He and Ar. II. Nuclear pumping, QUANTUM EL, 29(8), 1999, pp. 687-693
Citations number
26
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
QUANTUM ELECTRONICS
ISSN journal
10637818 → ACNP
Volume
29
Issue
8
Year of publication
1999
Pages
687 - 693
Database
ISI
SICI code
1063-7818(199908)29:8<687:KOTAMO>2.0.ZU;2-N
Abstract
The results of calculations based on a new detailed nonsteady-state multiwa ve kinetic model of a laser based on xenon atom transitions with lambda = 1 .73, 2.03, 2.65, 2.63, 3.37, and 3.51 mu m in an He-Ar-Xe mixture were comp ared with the results of experimental studies of a nuclear-pumped xenon las er carried out making use of several experimental setups. A satisfactory ag reement between the calculations and experiments was achieved. The causes o f the impairment of the nuclear-pumped xenon laser characteristics with inc rease in the temperature of the medium were discovered. It was found that n uclear pumping of a Ar-Xe mixture can result in attaining a lasing efficien cy up to 3.5%. A laser nuclear-pumped by the VIR-2M reactor was fully optim ised.