Ef. Passos et al., Predicting the cutting time of coagulating milk for cheese production using a heated thermistor, J FOOD SCI, 64(5), 1999, pp. 879-882
Based on an observed decrease of effective thermal conductivity of milk dur
ing coagulation, a heated thermistor sensor was developed for monitoring cu
rd formation. The thermistor was heated with a constant direct current, and
its voltage was measured during milk coagulation, indicating a drop after
the enzymatic reaction. The sensor was studied in the laboratory for differ
ent milk acidities, rennet concentrations, added calcium chloride, and coag
ulation temperatures. It was also tested in a commercial cheese plant for m
ore than a month. The cutting time established by the cheesemaker in 16 exp
eriments was compared with a prediction equation, and the standard error of
prediction was 1.9 min.