A new method for the evaluation of fast gas sensors is described. By using
moving gas outlets, we can quickly change the ambient around a sensor. Diff
erent platinum-insulator-silicon carbide (MISiC) structures are investigate
d. Their sensor response contains fast components, which respond within mil
liseconds to a change in the ambient from a reducing gas to an oxidising ga
s and vice versa. Cylinder specific monitoring of car engines with the MISi
C structures is discussed. (C) 1999 Elsevier Science S.A. AU rights reserve
d.