Flow measurement according to the acoustical transit time method at disturbed profiles in cylindric tubes

Authors
Citation
J. Gatke, Flow measurement according to the acoustical transit time method at disturbed profiles in cylindric tubes, TEC MES, 66(10), 1999, pp. 378-385
Citations number
8
Categorie Soggetti
Instrumentation & Measurement
Journal title
TECHNISCHES MESSEN
ISSN journal
01718096 → ACNP
Volume
66
Issue
10
Year of publication
1999
Pages
378 - 385
Database
ISI
SICI code
0171-8096(199910)66:10<378:FMATTA>2.0.ZU;2-U
Abstract
The ultrasonic flow metering technique has become an important method in re sidential and industrial applications. Especially for commercial purposes i t is a necessity to get notice of the measuring errors and their reasons. This paper describes the influence of disturbed profiles on the behaviour o f ultrasonic flow meters and the possibility to minimize the errors.