Direct aortic cannulation for port-access mitral or coronary artery bypassgrafting

Citation
Dd. Glower et al., Direct aortic cannulation for port-access mitral or coronary artery bypassgrafting, ANN THORAC, 68(5), 1999, pp. 1878-1880
Citations number
6
Categorie Soggetti
Cardiovascular & Respiratory Systems","Medical Research Diagnosis & Treatment
Journal title
ANNALS OF THORACIC SURGERY
ISSN journal
00034975 → ACNP
Volume
68
Issue
5
Year of publication
1999
Pages
1878 - 1880
Database
ISI
SICI code
0003-4975(199911)68:5<1878:DACFPM>2.0.ZU;2-C
Abstract
A technique is described for direct aortic arterial cannulation during Port -Access mitral valve or coronary artery bypass grafting. Femoral arterial c annulation is avoided, and endoaortic balloon occlusion is used for cardiop legic arrest. To date, excellent results have been obtained in 45 patients. (C) 1999 by The Society of Thoracic Surgeons.