The coupling of an absorption-refrigerator with a co-generation system

Citation
P. Le Goff et Jm. Hornut, The coupling of an absorption-refrigerator with a co-generation system, CHEM ENG R, 77(A7), 1999, pp. 663-668
Citations number
10
Categorie Soggetti
Chemical Engineering
Journal title
CHEMICAL ENGINEERING RESEARCH & DESIGN
ISSN journal
02638762 → ACNP
Volume
77
Issue
A7
Year of publication
1999
Pages
663 - 668
Database
ISI
SICI code
0263-8762(199910)77:A7<663:TCOAAW>2.0.ZU;2-3
Abstract
Three methods are proposed for coupling a conventional co-generation system with a refrigerator operating partly by compression, using cheap electrici ty at off-peak hours, and partly by absorption using waste heat or even exc ess heat produced in summer. The system uses a binary mixture (i.e. ammonia + sodium thiocyanate) with reservoirs for storing the separated components . This constitutes an exergy storage system, for accommodating the fluctuat ions of shaft work, heat and cold demands.