The variation of Rn concentrations in 134 offices with different covering m
aterials cladded on internal building surfaces, including walls, ceilings a
nd floors, were measured. The three commonest combinations (87 sites of cov
ering materials for the walls, ceilings and floors in Hong Kong are (A): wa
ll paper, fibre board, carpet; (B): paint, paint and plastic tile and (C):
paint, fibre board, plastic tile. The average Rn concentrations for combina
tions (A) and (B) were about the same, while that for combination (C) was s
ignificantly lower than those for (A) and (B). A person working in an offic
e with combination (C) can receive an average annual tracheobronchial equiv
alent dose smaller than one working in an office with combinations (A) and
(B) by an amount as large as 0.8 mSv. (C) 1999 Elsevier Science Ltd. All ri
ghts reserved.