Optimal protocol for injection of contrast material at MR angiography: Study of healthy volunteers

Citation
K. Mitsuzaki et al., Optimal protocol for injection of contrast material at MR angiography: Study of healthy volunteers, RADIOLOGY, 213(3), 1999, pp. 913-918
Citations number
18
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging","Medical Research Diagnosis & Treatment
Journal title
RADIOLOGY
ISSN journal
00338419 → ACNP
Volume
213
Issue
3
Year of publication
1999
Pages
913 - 918
Database
ISI
SICI code
0033-8419(199912)213:3<913:OPFIOC>2.0.ZU;2-X
Abstract
Forty healthy volunteers, matched for age and body weight, underwent abdomi nal magnetic resonance angiography with gadopentetate dimeglumine administe red by using a power injector. Injection rates were 0.3, 1.0, 2.0, or 3.0 m L/sec. Contrast material doses were 0.1 (single dose) or 0.2 (double dose) mmol/kg. increased contrast enhancement high flow rate and minimum arteriov enous overlap can be achieved with high flow rate and double-dose injection .