K. Mitsuzaki et al., Optimal protocol for injection of contrast material at MR angiography: Study of healthy volunteers, RADIOLOGY, 213(3), 1999, pp. 913-918
Citations number
18
Categorie Soggetti
Radiology ,Nuclear Medicine & Imaging","Medical Research Diagnosis & Treatment
Forty healthy volunteers, matched for age and body weight, underwent abdomi
nal magnetic resonance angiography with gadopentetate dimeglumine administe
red by using a power injector. Injection rates were 0.3, 1.0, 2.0, or 3.0 m
L/sec. Contrast material doses were 0.1 (single dose) or 0.2 (double dose)
mmol/kg. increased contrast enhancement high flow rate and minimum arteriov
enous overlap can be achieved with high flow rate and double-dose injection
.