The rotational measurement technique has been developed to measure the dyna
mic viscosity of liquid metals. A special procedure is accomplished to elim
inate both end and eccentricity effects. The technique was calibrated and t
ested with liquids of known rheology. The apparent viscosity of low melting
alloy composite is measured by means of the technique. (C) 1999 Acta Metal
lurgica Inc. Published by Elsevier Science Ltd. All rights reserved.