Determination of linear alkylbenzenesulfonates in communal wastewater by means of solid phase microextraction coupled with API-MS and HPLC-FLD

Citation
U. Ceglarek et al., Determination of linear alkylbenzenesulfonates in communal wastewater by means of solid phase microextraction coupled with API-MS and HPLC-FLD, FRESEN J AN, 365(8), 1999, pp. 674-681
Citations number
20
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences
Journal title
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY
ISSN journal
09370633 → ACNP
Volume
365
Issue
8
Year of publication
1999
Pages
674 - 681
Database
ISI
SICI code
0937-0633(199912)365:8<674:DOLAIC>2.0.ZU;2-0
Abstract
The use of Solid Phase Microextraction (SPME) for the qualitative and quant itative determination of Linear Alkylbenzesesulfonates (LAS) in waste water samples was investigated. A Carbowax/Templated Resin (CW/TPR) coated fiber was directly immersed into influent and effluent samples of a sewage treat ment plant (STP). Extraction conditions such as time, pH, ion strength were investigated. The extracted LAS were desorbed with a solvent in a speciall y designed SPME-LC interface for analysis with HPLC-FLD and Electrospray Io nization Mass Spectrometry (ESI-MS). The combination of SPME with ESI-MS pr oved Co bean alternative technique for the LAS determination in waste water . Linear ranges of the external calibration were found from 0.5-100 ng/mL, with detection limits of 0.5 ng/mL for each individual LAS homologue. The r eproducibility of the method is 15% (relative standard deviation).