The KLL and KLX Auger spectra of Cd from the EC-decay of In-111 have been a
nalyzed with the 7 eV instrumental resolution using a combined electrostati
c spectrometer and a source prepared by a modified Langmuir-Blodgett method
. Energies and relative intensities of all the nine well resolved KLL lines
have been precisely determined. While the latter quantities were found to
be in very good agreement with the relativistic intermediate coupling calcu
lations, the former ones deviate from results of the widely used semi-empir
ical calculations especially in the case of the absolute energies. The pred
icted strong influence of the relativistic effects on the KL1L2(P-3(0)) tra
nsition intensity has been proved. Most of the main KLX Auger lines have be
en well separated and their complex structures have been observed. Accurate
energies and intensities obtained for these lines have been compared with
results of calculations. The intermediate coupling splitting of the KL2L2 a
nd KL3L3 lines have been revealed. The KLX/KLL, KLN(O)/KLM, and KXY/KLL gro
up intensity ratios have also been determined. A conclusion is made that fu
rther finer theoretical investigation on the complex interaction mechanism
for two inner-shell vacancies is still very much needed. (C) 1999 Elsevier
Science B.V. All rights reserved.