E. Urbanovici et al., Improved iterative version of the Coats-Redfern method to evaluate non-isothermal kinetic parameters, J THERM ANA, 58(3), 1999, pp. 683-700
An improved version of the Coats-Redfern method of evaluating non-isotherma
l kinetic parameters is presented. The Coats-Redfern approximation of the t
emperature integral is replaced by a third-degree rational approximation, w
hich is much more accurate. The kinetic parameters are evaluated iterativel
y by linear regression and, besides the correlation coefficient, the F test
is suggested as a supplementary statistical criterion for selecting the mo
st probable mechanism function. For applications, both non-isothermal data
obtained by theoretical simulation and experimental data taken from the lit
erature for the non-isothermal dehydration of Mg(OH)(2) have been processed
.