Twelve years' continuous wear of the same therapeutic soft contact lens: acase report

Citation
S. Kokolakis et al., Twelve years' continuous wear of the same therapeutic soft contact lens: acase report, EUR J OPTHA, 9(4), 1999, pp. 312-314
Citations number
6
Categorie Soggetti
Optalmology
Journal title
EUROPEAN JOURNAL OF OPHTHALMOLOGY
ISSN journal
11206721 → ACNP
Volume
9
Issue
4
Year of publication
1999
Pages
312 - 314
Database
ISI
SICI code
1120-6721(199910/12)9:4<312:TYCWOT>2.0.ZU;2-X
Abstract
Purpose. To describe a case of a patient who had worn the same therapeutic soft contact lens (TSCL) continuously for twelve years, since he had failed to attend normal follow-up visits. Methods. Microbiological histological and scanning electron microscopic (SE M) studies of conjunctiva, cornea and TSCL were done. Results. Cultures were negative. Corneal histology revealed mild stromal ed ema and mild epithelial parakeratosis. Corneal SEM was remarkable for the p reservation to some extent of normal corneal epithelial specialization with microtricae and microvillae. SEM of the TSCL showed a ruffed multi-layer s urface with several cracks including different types of cells. Conclusions. The patient showed surprising tolerance to the continuous wear of the same contact lens for 12 years.