Durability testing for the recovery of sodium hydroxide from alkaline waste solutions

Citation
Jd. Genders et al., Durability testing for the recovery of sodium hydroxide from alkaline waste solutions, J APPL ELEC, 30(1), 1999, pp. 13-19
Citations number
12
Categorie Soggetti
Physical Chemistry/Chemical Physics
Journal title
JOURNAL OF APPLIED ELECTROCHEMISTRY
ISSN journal
0021891X → ACNP
Volume
30
Issue
1
Year of publication
1999
Pages
13 - 19
Database
ISI
SICI code
0021-891X(1999)30:1<13:DTFTRO>2.0.ZU;2-4
Abstract
Testing successfully demonstrated the operation of an electrochemical flow cell for more than 1000 h to recover 13-14 wt% sodium hydroxide from an alk aline waste solution. The nickel cathode, platinized-titanium anode and cat ionic membrane exhibited no visible signs of attack upon inspection after t esting. The membrane experienced a slow, but steady decline in current effi ciency, from a high of greater than 95% down to approximately 90% after 107 9 h. We attribute the loss in current efficiency to the accumulation of sil icon and aluminium within the membrane structure.