X-ray conversion with PHEBUS laser

Citation
D. Babonneau et al., X-ray conversion with PHEBUS laser, LASER PART, 17(3), 1999, pp. 459-463
Citations number
5
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science
Journal title
LASER AND PARTICLE BEAMS
ISSN journal
02630346 → ACNP
Volume
17
Issue
3
Year of publication
1999
Pages
459 - 463
Database
ISI
SICI code
0263-0346(1999)17:3<459:XCWPL>2.0.ZU;2-X
Abstract
A time-resolved X-ray conversion efficiency campaign was conducted at CEA/L imeil-Valenton on the PHEBUS laser, with Au planar targets. The calibrated diagnostic DEMIXART has measured X-ray emissions driven by shaped laser pul ses. The results have been analyzed with the "physicist" 1D1/2 hydrodynamic al code CHIVAS, where improved transport coefficients have been implemented . The influence of the degeneracy and solid/liquid corrections on various p arameters is shown. Other significant effects due to focal: spot shapes and lateral conduction are quantified with the FCI2 hydroradiative code of CEA /DRIF.