Temperature characteristics of the radiation detector using the TlBr crystals

Citation
T. Shoji et al., Temperature characteristics of the radiation detector using the TlBr crystals, IEEE NUCL S, 46(6), 1999, pp. 1934-1937
Citations number
6
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Nuclear Emgineering
Journal title
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
ISSN journal
00189499 → ACNP
Volume
46
Issue
6
Year of publication
1999
Part
2
Pages
1934 - 1937
Database
ISI
SICI code
0018-9499(199912)46:6<1934:TCOTRD>2.0.ZU;2-5
Abstract
The radiation detector was fabricated from the TlBr crystals grown by TMZ ( travelling molten zone) method and the FWHM and transit time of electrons a nd holes were measured as a function of temperature. The TlBr radiation det ector shows the best response characteristics at about 313 K (3.19K(-1)) in cases where holes mainly contributed to the output pulses. However, in the temperatures higher than 300 K (3.33 K-1), the FWHM for Am-241 alpha-parti cles (5.48 MeV) becomes worse. An activation energy of about 0.90eV has bee n deduced from the resistivity measurement.