Enantioseparation of thalidomide and its hydroxylated metabolites using capillary electrophoresis with various cyclodextrins and their combinations as chiral buffer additives
M. Meyring et al., Enantioseparation of thalidomide and its hydroxylated metabolites using capillary electrophoresis with various cyclodextrins and their combinations as chiral buffer additives, ELECTROPHOR, 20(12), 1999, pp. 2425-2431
The separation of thalidomide (TD) and its hydroxylated metabolites includi
ng their simultaneous enantioseparation was studied in capillary electropho
resis (CE) using four different randomly substituted charged cyclodextrin (
CD) derivatives, the combinations of some of them with each other, and beta
-CD. TD, as well as two metabolites recently found in incubations of human
liver microsomes and human blood, 5-hydroxythalidomide (5-OH-TD) and one of
the diastereomeric 5'-hydroxythalidomides (5'-OH-TD), are neutral compound
s. Therefore, they were resolved using charged chiral selectors in CE. Two
different separation modes (normal polarity and carrier mode) and two diffe
rent capillaries (fused-silica and polyacrylamide-coated) were tested. Base
d on the behavior of the individual CDs, their designed combinations were s
elected in order to improve the separation selectivity and enantioselectivi
ty. Under optimized conditions all three chiral compounds and their enantio
mers were resolved simultaneously.